0

The Premium Edge Protection Fencing System

AdaptaPanel Post and Panel Edge Protection System

AdaptaPanel Post and Panel Edge Protection System

The Premium Edge Protection Fencing System

Modular Post-and-Panel Protection for Slab Edges, Excavations and Changing Workfaces

AdaptaPanel is a modular post and panel edge protection system for construction, civil works, infrastructure and industrial sites, suited to contractors, temporary-works engineers, site safety managers, and Tier 1 to Tier 3 builders that need verified, engineered barriers for changing workfaces.

Its hot-dip galvanised steel posts and framed mesh edge protection panels surround voids and edges during construction to protect against falls from height, and can be configured around slab edges, capping beams, excavations, shafts, voids, façades and public interfaces. Posts are available from 1 m to 4 m high, with top-mounted, face-mounted, counterweighted and project-specific installation options.

Unlike lightweight mesh fencing, these edge protection panels use welded box-section frames and secured slide-in panels. Sliding safety latches retain the panels and help prevent unintentional lift-off.

The system can be dismantled, transported in stillages and reused as the project moves from one work area or construction stage to another. This page covers the AdaptaPanel system’s design features, mounting options, standards-led compliance, custom configurations, installation support and typical project applications, so you can assess the right edge protection setup with fewer safety, engineering and approval risks.

Why Choose AdaptaPanel?

Designed for Temporary Works Approval

AdaptaPanel is more than a collection of posts and mesh panels. It is a documented temporary-works system that can be configured, engineered and submitted for project approval without unnecessarily delaying the construction programme.

SafeSmart can provide assistance with approvals and project delivery, including:

  • Site-specific configuration drawings
  • Fixing and connection details
  • Engineering calculations
  • Design certification
  • Installation documentation
  • Inspection information
  • Documentation for independent third-party review
  • On-site installation support

Using an established system gives the temporary-works engineer a known design and tested component set to assess. This can reduce late redesign, rejected submissions, fixing changes and replacement of unsuitable equipment after it reaches site, which means smoother approvals when the system is installed and maintained properly for safe performance. Using an established system also helps ensure safety and greater confidence during review and approval.

Supporting Tier 1 and Tier 2 Construction Programmes

Tier 1 and Tier 2 contractors commonly require temporary edge protection to pass their project engineering and temporary-works approval processes before installation.

AdaptaPanel is designed and tested to meet the relevant requirements of AS/NZS 4994.1:2023 for temporary edge protection, and its edge protection fencing, panels and posts also comply with AS/NZS 4994.1:2009.

Where the system is incorporated into a fixed walkway, platform or ongoing access arrangement, the complete configuration can also be assessed against the relevant requirements of AS 1657:2018.

This gives the head contractor, temporary-works coordinator and reviewing engineer a documented approval pathway for a safe installation, covering the panels, posts, fixings, substrate, applied loads and site configuration.

The modular system can also be adapted as the programme changes. Top-mounted, face-mounted, counterweighted, shallow-embedment and custom configurations allow the edge protection to be planned around concrete pours, excavation stages, façade installation and changing work areas.

Reducing Approval Risk for Tier 3 Contractors

Tier 3 contractors working on Tier 1 or Tier 2 projects will often be required to provide engineering information and third-party verification for the edge protection they supply or install.

A cheaper system may appear to reduce the purchase cost. That saving can disappear if:

  • The project engineer cannot approve the system
  • Test evidence is unavailable
  • The fixings are unsuitable for the substrate
  • The barrier does not meet the required loading
  • The arrangement does not address AS 1657 where a fixed walkway is involved
  • Components must be modified or replaced
  • Installation is delayed while new drawings are prepared
  • The subcontractor must return to rectify the installation

WHS responsibilities can be shared across the contracting chain. A subcontractor cannot assume that the head contractor carries all responsibility if an incident occurs. Each contractor retains duties for the work and decisions within its influence or control.

Selecting a documented, engineered system helps the subcontractor demonstrate that the barrier was properly designed, reviewed, installed and inspected.

A System Built for Approval and Construction

AdaptaPanel gives contractors:

  • Tested performance across post heights from 1 m to 4 m
  • AS/NZS 4994.1:2023 temporary edge protection capability
  • AS 1657:2018 design capability where the configuration forms part of fixed access
  • Standard and site-specific engineering options
  • Documentation suitable for third-party review
  • Multiple mounting methods for changing construction stages
  • Post and panel edge protection that can be reused across multiple projects
  • Installation support and ongoing inspection documentation

Choose the documented system your engineer can review before it reaches site; it’s the ideal option to assess early, not one your crew may have to replace after installation.

AdaptaPanel Heights and Applications

edge protection post Mounting options Typical applications
1.0 m Top mount and face mount General edge protection, voids, site delineation and viewing screens
1.5 m Top mount and face mount Capping beams and construction perimeters requiring a taller barrier
2.0 m Top mount, face mount and cranked post Deep shafts, crane perimeter exclusion zones, security fencing, acoustic curtains and public interfaces
3.0 m Top mount and custom face mount Stepped capping beams, station boxes, screens and areas requiring greater containment
4.0 m Top mount and project-specific Station box voids, public interfaces and tall edge protection screens

The required height depends on the edge, fall distance, falling-object risk, public interface, attached materials, wind loading and project standards. Taller panel arrangements can also provide a clear visual boundary for workers in higher-risk areas.

Top-Mounted AdaptaPanel

Top-mounted posts are fixed to the horizontal surface of a concrete slab, beam or structure, and the post can be fixed to concrete using a base plate or flange depending on the mounting detail.

This configuration is commonly used for:

  • Slab-edge protection
  • Voids and penetrations
  • Capping beams
  • Retaining walls
  • Excavation perimeters
  • Station boxes
  • Security screens
  • Perimeter exclusion zones

Top-mounted posts are available in 1 m, 1.5 m, 2 m, 3 m and 4 m heights. Each post features a bolted base plate for secure installation, and edge protection posts can be fixed to concrete using a 152mm square flange where specified.

Standard concrete configurations use four concrete screw anchors with 90 mm embedment, bolting securely through the fixing plate when fixed to concrete using the specified anchor arrangement. The correct anchor size, concrete strength, edge distance and installation method must be confirmed for the project.

Face-Mounted AdaptaPanel

Face-mounted posts attach to the vertical face of a slab, capping beam or wall.

This keeps the top surface clear for walkways, storage, formwork and other construction activity. It can also reduce interference where the available space between a capping beam and site boundary is limited.

Face-mounted posts are available in:

  • 1.0 m
  • 1.5 m
  • 2.0 m
  • Custom 3.0 m configurations

Face mounting is commonly used around:

  • Capping beams
  • Basement excavations
  • Bridge structures
  • Retaining walls
  • Slab edges
  • Deep pits
  • Areas with restricted walkway space

See AdaptaPanel face-mounted edge protection at Castle Hill

Counterweighted AdaptaPanel

The AdaptaPanel Counterweight System can be used where drilling or permanent fixings are restricted.

The system uses galvanised base sections and 22.5 kg counterweights to support standard AdaptaPanel posts and mesh panels.

Base sections are available in 0.8 m, 1.0 m and 1.2 m lengths. Shorter bases may require more counterweight.

Every counterweighted configuration must be supported by temporary-works design. Wind loading, surface conditions, barrier height, counterweight quantities and clearance around the base must be assessed for the application.

Cranked Posts for Visibility into Excavations

The 2 m AdaptaPanel cranked post moves the upper barrier away from the operator’s direct sightline.

This allows crane operators, dogmen and other personnel to look down into shafts or excavations while a barrier remains between the person and the edge.

The cranked configuration is suited to:

  • Crane observation points
  • Station boxes
  • Deep shafts
  • Excavation viewing platforms
  • Material landing areas

Read how a cranked AdaptaPanel post improved visibility into a 30 m excavation

Sliding Panels and Access Gates

AdaptaPanel can include controlled openings for easy access without removing a complete barrier run.

Access openings still need to maintain protection against falls and falling objects; integrated kick plates prevent loose objects from rolling off the edge and help protect workers below.

Sliding Panels

Panels with sliding windows can provide:

  • Survey access
  • Temporary service openings
  • Viewing points for riggers and dogmen
  • Controlled observation points
  • Access around changing work areas

Swing Gates

A dedicated swing gate can create a defined access point through the barrier and include a secure lock for controlled access.

Gates can be used for:

  • Exclusion-zone entry
  • Temporary fencing access
  • Crane loading areas
  • Material movement
  • Personnel access

Gate locations and opening directions should be included in the edge protection layout before installation so gates easily lock in the approved position after installation.

AdaptaPanel WorkThru for Façade Installation

AdaptaPanel WorkThru is designed for work that must continue through or directly behind the edge protection.

Traditional fixed panels can restrict access to the slab edge during curtain wall, glazing and cladding installation. Removing complete barrier sections can then create new access and fall-protection requirements, even though the surrounding barrier is there to prevent workers, tools and materials from falling off exposed edges while work continues.

WorkThru uses removable mesh panels, or infill panels, sliding toeboards and adjustable sections so crews can access the workface while the surrounding barrier remains in position, with an open-mesh design that maintains light and airflow around the workface.

Applications include:

  • Curtain wall installation
  • Façade glazing
  • Cladding installation
  • Risers and voids
  • Corners
  • Crane ties
  • Screen ties
  • Alimak ties
  • Columns and protruding elements
  • Changing construction workfaces

WorkThru panels are available in 1 m, 1.5 m and 2 m lengths. An optional slider can extend up to 1 m, while adjoining sections can overlap by up to 300 mm.

The system can be positioned from 100 mm behind the slab edge and has a footprint of approximately 180 mm. This leaves more space behind the panel for workers and façade materials.

Optional components include:

  • Removable mesh
  • Sliding and overlapping toeboards
  • Adjustable sliding panels
  • Gates
  • Independent harness anchor brackets
  • Vertical debris netting
  • Horizontal catch fan netting
  • 3 m debris-netting support posts

The selected work method, access openings, harness provisions and panel removal sequence must be approved for the project.

Read about the latest AdaptaPanel WorkThru features

AdaptaPanel for CLT and Timber Structures

Concrete anchors cannot be transferred directly to cross-laminated timber. Timber has different pull-out characteristics and requires fixings selected for the substrate and applied loads.

SafeSmart can configure AdaptaPanel with timber construction screws and project-specific engineering.

For Buildcorp’s The Bond project in Bella Vista, AdaptaPanel was paired with HDC-P and HDC-C timber construction screws. This allowed edge protection to be installed on the imported CLT structure during construction and fit-out.

Read the Buildcorp CLT edge protection case study

Curved Edges and Circular Shafts

AdaptaPanel can follow circular shafts and curved building edges.

The 1 m and 2 m panels can be angled from the post to approximately 145 degrees. This allows the standard system to form a barrier around circular excavations with an internal diameter of approximately 7 m.

Tighter curves, irregular shapes and changing radiuses may require shorter panels, custom infills or a project-specific layout.

Custom AdaptaPanel Configurations

Sacrificial Baseplates

Sacrificial baseplates can be cast into a continuous concrete pour. The baseplates remain in the concrete while the posts and panels are removed and reused at the next stage.

This reduces component waste and allows edge protection to progress with consecutive pours.

Cast-In Sleeve Baseplates

Steel sleeves can be cast into the slab where exposed bolt-down fixings are unsuitable.

AdaptaPanel posts are manufactured with a welded spigot that slides into the cast-in sleeve. This provides a removable post without surface-mounted fixings.

Custom Infill Panels

Angular and irregular infill panels can close gaps created by changing beam levels, corners and site geometry.

For the Sydney Metro Central Tunnelling Project, SafeSmart produced angular infill panels that followed changes in the capping-beam profile.

Corner Posts

Left-hand and right-hand corner posts connect panels at changes in direction while reducing the number of separate posts required.

Shallow Embedment Posts

Selected 2 m top-mounted and face-mounted configurations can be designed with approximately 50 mm anchor embedment.

Shallow embedment is not a standard substitute for the normal fixing arrangement. It requires site-specific temporary-works design covering the substrate, anchor arrangement, edge distances and applied loads.

Acoustic Curtains and Screens

AdaptaPanel posts can support acoustic curtains, screening and other attached materials.

Any solid or semi-solid covering changes the wind load transferred into the posts, anchors and supporting structure. The complete covered configuration must be reviewed before installation.

Common AdaptaPanel Applications

  • High-rise slab edges
  • General building construction across a wide application range
  • Data centres
  • Capping beams
  • Basement excavations
  • Deep shafts
  • Tunnel station boxes
  • Bridge and infrastructure projects
  • Voids and risers
  • stairwells
  • lift shafts
  • Circular excavations
  • Crane perimeter exclusion zones
  • Public-interface barriers
  • Security fencing
  • Viewing screens
  • Façade and curtain wall installation
  • Acoustic barriers
  • Cross-laminated timber buildings
  • Conveyor and plant guarding
  • Continuous concrete pours
  • Temporary service openings

AdaptaPanel Components and 50mm Square Sections

Top-Mount Posts

Code (SKU) Component
210842 1.0 m top-mount post
210843 1.5 m top-mount post
210875 2.0 m top-mount post
210876 3.0 m top-mount post
210966 4.0 m top-mount post

Standard edge protection post note: the standard rhs post is made from galvanised 50mm square RHS and vertical posts are usually constructed from heavy-duty galvanised steel. Where applicable, standard edge protection posts are 1005mm high for effective edge protection and compliance.

Face-Mount and Special Edge Protection Posts

Code Component
210870 1.0 m face-mount post
210871 1.5 m face-mount post
210872 2.0 m face-mount post
210873 2.0 m left-hand corner post
210874 2.0 m right-hand corner post
210965 2.0 m cranked post

Edge Protection Panels, Mesh Panels and Access Components

Code Component
210844 Mesh panel, 0.5 m high x 1.0 m long
210845 Mesh panel, 0.5 m high x 2.0 m long
210846 Mesh panel, 1.0 m high x 1.0 m long
210847 Mesh panel, 1.0 m high x 2.0 m long
210964 Mesh panel with sliding window
210146 AdaptaPanel swing gate

Note: Each galvanised welded mesh panel comprises 4mm steel wire construction with 50mm grid centres, with rolled wire edge detailing for added strength.

Counterweight Components

Code Component
210576 Counterweight base section, 0.8 m
210577 Counterweight base section, 1.0 m
210578 Counterweight base section, 1.2 m
210579 Galvanised counterweight, 22.5 kg

Impact Testing and Standards

AdaptaPanel is designed and tested to meet the relevant requirements of:

  • AS/NZS 4994.1:2023: Temporary edge protection
  • AS 1657:2018: Fixed platforms, walkways, stairways and ladders, where applicable

The system is tested at the top rail height for its different post heights.

SafeSmart’s testing includes:

  • A 600 N horizontal point load
  • A 350 N/m horizontal distributed load
  • A maximum deflection limit of 100 mm

Testing the load at the top of taller posts is important. Applying a compliant load only at a traditional 1 m rail height does not represent the force placed on a 2 m, 3 m or 4 m barrier.

Compliance depends on the complete configuration, including:

  • Post height
  • Panel arrangement
  • Fixing method
  • Anchor type
  • Concrete or timber substrate
  • Edge distance
  • Attached mesh, curtains or screening
  • Wind loading
  • Gates and openings
  • Installation and inspection

From Site Scoping to Installation

AdaptaPanel is supplied as a configurable system rather than a single standard fence panel, which makes installation easier to plan across different site conditions.

SafeSmart can work with the site, engineering and temporary-works teams to determine:

  • Required barrier heights
  • Top or face mounting
  • Concrete, steel or timber substrates
  • Standard or shallow embedment
  • Counterweight requirements
  • Where to place posts and panels
  • Corners and changes in level
  • Gates and material access
  • Façade work areas
  • Public-interface requirements
  • Wind and attached screening loads
  • Installation stages
  • Storage and relocation
  • Proper installation and maintenance requirements for safety throughout the project lifecycle

The resulting package can include site measurements, layout drawings, engineering calculations, certification, custom components, manufacture, delivery, installer training, inspections and replacement parts.

AdaptaPanel Case Studies

Shellharbour Hospital: WorkThru Edge Protection

BESIX Watpac needed edge protection that could respond to voids, structural ties and changing work areas during the Shellharbour Hospital construction.

AdaptaPanel WorkThru allowed mesh sections to be removed where crews needed access. Sliding toeboards adjusted around ties, columns and void protection. SafeSmart also provided engineering support and on-site installation training.

Read the Shellharbour Hospital WorkThru case study

Castle Hill: Face-Mounted Capping Beam Protection

Dasco had limited room between a capping beam and the site’s perimeter fence. A top-mounted or freestanding barrier would have reduced the space available for storage and pedestrian movement.

SafeSmart supplied a 2 m face-mounted AdaptaPanel system. Fixing the posts to the side of the beam left the upper surface available as a walkway while also providing a taller barrier above the excavation.

Read the Castle Hill capping beam case study

Sydney Metro: Cranked Posts Above a Station Box

Crane operators working above a 30 m deep excavation needed visibility into the station box without leaning over the barrier.

SafeSmart worked with the project team to design a 45-degree cranked post using standard AdaptaPanel panels. The upper section moved away from the operator’s direct viewing line while retaining the required barrier height.

Read the Sydney Metro cranked-post case study

The Bond: Edge Protection on CLT

Buildcorp required edge protection for a cross-laminated timber structure at The Bond project in Bella Vista.

SafeSmart reviewed the lower pull-out strength of the timber substrate and paired standard AdaptaPanel components with selected timber construction screws. This allowed the system to be used during both construction and fit-out.

Read The Bond CLT edge protection case study

Frequently Asked Questions

Is AdaptaPanel temporary or permanent?

AdaptaPanel is primarily designed for temporary and semi-permanent edge protection. Some configurations may be used for longer periods, subject to the approved design, installation, inspection and maintenance requirements.

What heights are available?

Top-mounted posts are available in 1 m, 1.5 m, 2 m, 3 m and 4 m heights. Standard face-mounted posts are available in 1 m, 1.5 m and 2 m heights.

Can AdaptaPanel be installed without drilling?

Yes, in selected configurations. Counterweighted bases and cast-in sleeve systems can be used where surface drilling is restricted. These configurations require project-specific temporary-works design.

Can it be installed on timber?

Yes. The substrate and fixings must be assessed for the timber structure. Standard concrete anchors must not be used as a timber fixing schedule.

Can it follow curved edges?

Yes. Standard panels can be angled at the posts to follow broad curves and circular shafts. Tighter radiuses may require shorter panels or custom infill sections.

Can mesh panels be removed for work at the edge?

The standard system uses retained slide-in panels. Where work must continue through the barrier, AdaptaPanel WorkThru provides removable mesh, sliding toeboards and controlled access components. Integrated kick plates help prevent loose objects from rolling off the edge and reduce the risk of falling objects hitting workers below.

Can screening or acoustic curtains be attached?

Yes, subject to design. Curtains, shade mesh and solid screening increase wind loads and may require different posts, fixings or spacing.

How is the system transported?

Posts and panels can be stacked in dedicated stillages for storage and secured transport.

Does every AdaptaPanel configuration comply automatically?

No. AdaptaPanel components are designed and tested against the relevant standards, but compliance applies to the approved complete configuration. Fixings, substrate, layout, height, loads and installation must all be checked.

More AdaptaPanel Information

Need Edge Protection for a Changing Workface?

Send SafeSmart your drawings, perimeter lengths, required heights, substrate details, construction sequence and access requirements so we can plan project-specific layouts and fixings designed specifically for the build sequence.

Our team can scope, design, engineer and deliver an AdaptaPanel edge protection system around the way the project will actually be built, helping keep changing workfaces protected and reduce risks from falls.

  • Temporary and semi-permanent slab edge protection fencing.
  • Heavy duty framed panel for longevity in harsh site conditions.
  • Posts bolt to slab edge, and slide-in panels are secured with a fixing bolt.
  • Sliding safety latches retain mesh panels, preventing unintentional lift-off.
  • The 1.5mH & 2.0mH panels are ideal for high rise construction and to assist with PEZ (Perimeter Exclusion Zone)
  • Ideal for high rise construction, retaining walls, capping beams, and deep excavations.
  • Panels may be stacked for easy storage and transportation.
  • Designed to meet relevant design and load requirements of AS/NZS 4994.1:2009 Temporary edge protection standard and AS 1657 : 2018.
  • Used at Rozelle Interchange and Major Sydney Tunnel construction projects.

AdaptaPanel Calculator

Enter your linear metres to see a detailed component breakdown.

Mount Type

Your Project Summary

View your component summary below.

Selections

Mount Type:

Not Selected

Panel Height(m):

Not Selected

Panel Length(m):

Not Selected

Adaptapanel face mount 1.png

Materials Estimate

Component breakdown based on your input value of 0 linear metres.

Number of Posts

 

Number of Panels

 

SKU: 210870
AdaptaPanel - Edge Protection Face Mount Post 1.0mH
  • AdaptaPanel Edge Protection Face Mount Post - 1.0mH
SKU: 210871
AdaptaPanel - Edge Protection Face Mount Post 1.5mH
  • AdaptaPanel Edge Protection Face Mount Post - 1.5mH
SKU: 210872
AdaptaPanel - Edge Protection Face Mount Post 2.0mH
  • AdaptaPanel Edge Protection Face Mount Post - 2.0mH
SKU: 210842
AdaptaPanel - Edge Protection Post 1m Height
  • AdaptaPanel Edge Protection Post - 1.0mH
SKU: 210843
AdaptaPanel - Edge Protection Post 1.5m Height
  • AdaptaPanel Edge Protection Post - 1.5mH
SKU: 210875
AdaptaPanel - Edge Protection Post 2m Height
  • AdaptaPanel Edge Protection Post - 2.0mH
SKU: 210876
AdaptaPanel - Edge Protection Post 3m Height
  • AdaptaPanel Edge Protection Post - 3.0mH
SKU: 210844
AdaptaPanel - Mesh Fence Panel 0.5 x 1.0m
  • AdaptaPanel Mesh Fence Panel - 0.5mH x 1.0mL
SKU: 210845
AdaptaPanel - Mesh Fence Panel 0.5 x 2.0m
  • AdaptaPanel Mesh Fence Panel - 0.5mH x 2.0mL
SKU: 210846
AdaptaPanel - Mesh Fence Panel 1.0 x 1.0m
  • AdaptaPanel Mesh Fence Panel - 1.0mH x 1.0mL
SKU: 210847
AdaptaPanel - Mesh Fence Panel 1.0 x 2.0m
  • AdaptaPanel Mesh Fence Panel - 1.0mH x 2.0mL
SKU: 210873
AdaptaPanel Edge Protection Left-Hand Corner Post - 2.0mH
  • AdaptaPanel Edge Protection Left-Hand Corner Post - 2.0mH
SKU: 210874
AdaptaPanel Edge Protection Right-Hand Corner Post - 2.0mH
  • AdaptaPanel Edge Protection Right-Hand Corner Post - 2.0mH
SKU: 210965
AdaptaPanel Edge Protection - Cranked Post - 2.0mH
  • AdaptaPanel Edge Protection - Cranked Post - 2.0mH

Product Description

Modular Post-and-Panel Protection for Slab Edges, Excavations and Changing Workfaces

AdaptaPanel is a modular post and panel edge protection system for construction, civil works, infrastructure and industrial sites, suited to contractors, temporary-works engineers, site safety managers, and Tier 1 to Tier 3 builders that need verified, engineered barriers for changing workfaces.

Its hot-dip galvanised steel posts and framed mesh edge protection panels surround voids and edges during construction to protect against falls from height, and can be configured around slab edges, capping beams, excavations, shafts, voids, façades and public interfaces. Posts are available from 1 m to 4 m high, with top-mounted, face-mounted, counterweighted and project-specific installation options.

Unlike lightweight mesh fencing, these edge protection panels use welded box-section frames and secured slide-in panels. Sliding safety latches retain the panels and help prevent unintentional lift-off.

The system can be dismantled, transported in stillages and reused as the project moves from one work area or construction stage to another. This page covers the AdaptaPanel system’s design features, mounting options, standards-led compliance, custom configurations, installation support and typical project applications, so you can assess the right edge protection setup with fewer safety, engineering and approval risks.

Why Choose AdaptaPanel?

Designed for Temporary Works Approval

AdaptaPanel is more than a collection of posts and mesh panels. It is a documented temporary-works system that can be configured, engineered and submitted for project approval without unnecessarily delaying the construction programme.

SafeSmart can provide assistance with approvals and project delivery, including:

  • Site-specific configuration drawings
  • Fixing and connection details
  • Engineering calculations
  • Design certification
  • Installation documentation
  • Inspection information
  • Documentation for independent third-party review
  • On-site installation support

Using an established system gives the temporary-works engineer a known design and tested component set to assess. This can reduce late redesign, rejected submissions, fixing changes and replacement of unsuitable equipment after it reaches site, which means smoother approvals when the system is installed and maintained properly for safe performance. Using an established system also helps ensure safety and greater confidence during review and approval.

Supporting Tier 1 and Tier 2 Construction Programmes

Tier 1 and Tier 2 contractors commonly require temporary edge protection to pass their project engineering and temporary-works approval processes before installation.

AdaptaPanel is designed and tested to meet the relevant requirements of AS/NZS 4994.1:2023 for temporary edge protection, and its edge protection fencing, panels and posts also comply with AS/NZS 4994.1:2009.

Where the system is incorporated into a fixed walkway, platform or ongoing access arrangement, the complete configuration can also be assessed against the relevant requirements of AS 1657:2018.

This gives the head contractor, temporary-works coordinator and reviewing engineer a documented approval pathway for a safe installation, covering the panels, posts, fixings, substrate, applied loads and site configuration.

The modular system can also be adapted as the programme changes. Top-mounted, face-mounted, counterweighted, shallow-embedment and custom configurations allow the edge protection to be planned around concrete pours, excavation stages, façade installation and changing work areas.

Reducing Approval Risk for Tier 3 Contractors

Tier 3 contractors working on Tier 1 or Tier 2 projects will often be required to provide engineering information and third-party verification for the edge protection they supply or install.

A cheaper system may appear to reduce the purchase cost. That saving can disappear if:

  • The project engineer cannot approve the system
  • Test evidence is unavailable
  • The fixings are unsuitable for the substrate
  • The barrier does not meet the required loading
  • The arrangement does not address AS 1657 where a fixed walkway is involved
  • Components must be modified or replaced
  • Installation is delayed while new drawings are prepared
  • The subcontractor must return to rectify the installation

WHS responsibilities can be shared across the contracting chain. A subcontractor cannot assume that the head contractor carries all responsibility if an incident occurs. Each contractor retains duties for the work and decisions within its influence or control.

Selecting a documented, engineered system helps the subcontractor demonstrate that the barrier was properly designed, reviewed, installed and inspected.

A System Built for Approval and Construction

AdaptaPanel gives contractors:

  • Tested performance across post heights from 1 m to 4 m
  • AS/NZS 4994.1:2023 temporary edge protection capability
  • AS 1657:2018 design capability where the configuration forms part of fixed access
  • Standard and site-specific engineering options
  • Documentation suitable for third-party review
  • Multiple mounting methods for changing construction stages
  • Post and panel edge protection that can be reused across multiple projects
  • Installation support and ongoing inspection documentation

Choose the documented system your engineer can review before it reaches site; it’s the ideal option to assess early, not one your crew may have to replace after installation.

AdaptaPanel Heights and Applications

edge protection post Mounting options Typical applications
1.0 m Top mount and face mount General edge protection, voids, site delineation and viewing screens
1.5 m Top mount and face mount Capping beams and construction perimeters requiring a taller barrier
2.0 m Top mount, face mount and cranked post Deep shafts, crane perimeter exclusion zones, security fencing, acoustic curtains and public interfaces
3.0 m Top mount and custom face mount Stepped capping beams, station boxes, screens and areas requiring greater containment
4.0 m Top mount and project-specific Station box voids, public interfaces and tall edge protection screens

The required height depends on the edge, fall distance, falling-object risk, public interface, attached materials, wind loading and project standards. Taller panel arrangements can also provide a clear visual boundary for workers in higher-risk areas.

Top-Mounted AdaptaPanel

Top-mounted posts are fixed to the horizontal surface of a concrete slab, beam or structure, and the post can be fixed to concrete using a base plate or flange depending on the mounting detail.

This configuration is commonly used for:

  • Slab-edge protection
  • Voids and penetrations
  • Capping beams
  • Retaining walls
  • Excavation perimeters
  • Station boxes
  • Security screens
  • Perimeter exclusion zones

Top-mounted posts are available in 1 m, 1.5 m, 2 m, 3 m and 4 m heights. Each post features a bolted base plate for secure installation, and edge protection posts can be fixed to concrete using a 152mm square flange where specified.

Standard concrete configurations use four concrete screw anchors with 90 mm embedment, bolting securely through the fixing plate when fixed to concrete using the specified anchor arrangement. The correct anchor size, concrete strength, edge distance and installation method must be confirmed for the project.

Face-Mounted AdaptaPanel

Face-mounted posts attach to the vertical face of a slab, capping beam or wall.

This keeps the top surface clear for walkways, storage, formwork and other construction activity. It can also reduce interference where the available space between a capping beam and site boundary is limited.

Face-mounted posts are available in:

  • 1.0 m
  • 1.5 m
  • 2.0 m
  • Custom 3.0 m configurations

Face mounting is commonly used around:

  • Capping beams
  • Basement excavations
  • Bridge structures
  • Retaining walls
  • Slab edges
  • Deep pits
  • Areas with restricted walkway space

See AdaptaPanel face-mounted edge protection at Castle Hill

Counterweighted AdaptaPanel

The AdaptaPanel Counterweight System can be used where drilling or permanent fixings are restricted.

The system uses galvanised base sections and 22.5 kg counterweights to support standard AdaptaPanel posts and mesh panels.

Base sections are available in 0.8 m, 1.0 m and 1.2 m lengths. Shorter bases may require more counterweight.

Every counterweighted configuration must be supported by temporary-works design. Wind loading, surface conditions, barrier height, counterweight quantities and clearance around the base must be assessed for the application.

Cranked Posts for Visibility into Excavations

The 2 m AdaptaPanel cranked post moves the upper barrier away from the operator’s direct sightline.

This allows crane operators, dogmen and other personnel to look down into shafts or excavations while a barrier remains between the person and the edge.

The cranked configuration is suited to:

  • Crane observation points
  • Station boxes
  • Deep shafts
  • Excavation viewing platforms
  • Material landing areas

Read how a cranked AdaptaPanel post improved visibility into a 30 m excavation

Sliding Panels and Access Gates

AdaptaPanel can include controlled openings for easy access without removing a complete barrier run.

Access openings still need to maintain protection against falls and falling objects; integrated kick plates prevent loose objects from rolling off the edge and help protect workers below.

Sliding Panels

Panels with sliding windows can provide:

  • Survey access
  • Temporary service openings
  • Viewing points for riggers and dogmen
  • Controlled observation points
  • Access around changing work areas

Swing Gates

A dedicated swing gate can create a defined access point through the barrier and include a secure lock for controlled access.

Gates can be used for:

  • Exclusion-zone entry
  • Temporary fencing access
  • Crane loading areas
  • Material movement
  • Personnel access

Gate locations and opening directions should be included in the edge protection layout before installation so gates easily lock in the approved position after installation.

AdaptaPanel WorkThru for Façade Installation

AdaptaPanel WorkThru is designed for work that must continue through or directly behind the edge protection.

Traditional fixed panels can restrict access to the slab edge during curtain wall, glazing and cladding installation. Removing complete barrier sections can then create new access and fall-protection requirements, even though the surrounding barrier is there to prevent workers, tools and materials from falling off exposed edges while work continues.

WorkThru uses removable mesh panels, or infill panels, sliding toeboards and adjustable sections so crews can access the workface while the surrounding barrier remains in position, with an open-mesh design that maintains light and airflow around the workface.

Applications include:

  • Curtain wall installation
  • Façade glazing
  • Cladding installation
  • Risers and voids
  • Corners
  • Crane ties
  • Screen ties
  • Alimak ties
  • Columns and protruding elements
  • Changing construction workfaces

WorkThru panels are available in 1 m, 1.5 m and 2 m lengths. An optional slider can extend up to 1 m, while adjoining sections can overlap by up to 300 mm.

The system can be positioned from 100 mm behind the slab edge and has a footprint of approximately 180 mm. This leaves more space behind the panel for workers and façade materials.

Optional components include:

  • Removable mesh
  • Sliding and overlapping toeboards
  • Adjustable sliding panels
  • Gates
  • Independent harness anchor brackets
  • Vertical debris netting
  • Horizontal catch fan netting
  • 3 m debris-netting support posts

The selected work method, access openings, harness provisions and panel removal sequence must be approved for the project.

Read about the latest AdaptaPanel WorkThru features

AdaptaPanel for CLT and Timber Structures

Concrete anchors cannot be transferred directly to cross-laminated timber. Timber has different pull-out characteristics and requires fixings selected for the substrate and applied loads.

SafeSmart can configure AdaptaPanel with timber construction screws and project-specific engineering.

For Buildcorp’s The Bond project in Bella Vista, AdaptaPanel was paired with HDC-P and HDC-C timber construction screws. This allowed edge protection to be installed on the imported CLT structure during construction and fit-out.

Read the Buildcorp CLT edge protection case study

Curved Edges and Circular Shafts

AdaptaPanel can follow circular shafts and curved building edges.

The 1 m and 2 m panels can be angled from the post to approximately 145 degrees. This allows the standard system to form a barrier around circular excavations with an internal diameter of approximately 7 m.

Tighter curves, irregular shapes and changing radiuses may require shorter panels, custom infills or a project-specific layout.

Custom AdaptaPanel Configurations

Sacrificial Baseplates

Sacrificial baseplates can be cast into a continuous concrete pour. The baseplates remain in the concrete while the posts and panels are removed and reused at the next stage.

This reduces component waste and allows edge protection to progress with consecutive pours.

Cast-In Sleeve Baseplates

Steel sleeves can be cast into the slab where exposed bolt-down fixings are unsuitable.

AdaptaPanel posts are manufactured with a welded spigot that slides into the cast-in sleeve. This provides a removable post without surface-mounted fixings.

Custom Infill Panels

Angular and irregular infill panels can close gaps created by changing beam levels, corners and site geometry.

For the Sydney Metro Central Tunnelling Project, SafeSmart produced angular infill panels that followed changes in the capping-beam profile.

Corner Posts

Left-hand and right-hand corner posts connect panels at changes in direction while reducing the number of separate posts required.

Shallow Embedment Posts

Selected 2 m top-mounted and face-mounted configurations can be designed with approximately 50 mm anchor embedment.

Shallow embedment is not a standard substitute for the normal fixing arrangement. It requires site-specific temporary-works design covering the substrate, anchor arrangement, edge distances and applied loads.

Acoustic Curtains and Screens

AdaptaPanel posts can support acoustic curtains, screening and other attached materials.

Any solid or semi-solid covering changes the wind load transferred into the posts, anchors and supporting structure. The complete covered configuration must be reviewed before installation.

Common AdaptaPanel Applications

  • High-rise slab edges
  • General building construction across a wide application range
  • Data centres
  • Capping beams
  • Basement excavations
  • Deep shafts
  • Tunnel station boxes
  • Bridge and infrastructure projects
  • Voids and risers
  • stairwells
  • lift shafts
  • Circular excavations
  • Crane perimeter exclusion zones
  • Public-interface barriers
  • Security fencing
  • Viewing screens
  • Façade and curtain wall installation
  • Acoustic barriers
  • Cross-laminated timber buildings
  • Conveyor and plant guarding
  • Continuous concrete pours
  • Temporary service openings

AdaptaPanel Components and 50mm Square Sections

Top-Mount Posts

Code (SKU) Component
210842 1.0 m top-mount post
210843 1.5 m top-mount post
210875 2.0 m top-mount post
210876 3.0 m top-mount post
210966 4.0 m top-mount post

Standard edge protection post note: the standard rhs post is made from galvanised 50mm square RHS and vertical posts are usually constructed from heavy-duty galvanised steel. Where applicable, standard edge protection posts are 1005mm high for effective edge protection and compliance.

Face-Mount and Special Edge Protection Posts

Code Component
210870 1.0 m face-mount post
210871 1.5 m face-mount post
210872 2.0 m face-mount post
210873 2.0 m left-hand corner post
210874 2.0 m right-hand corner post
210965 2.0 m cranked post

Edge Protection Panels, Mesh Panels and Access Components

Code Component
210844 Mesh panel, 0.5 m high x 1.0 m long
210845 Mesh panel, 0.5 m high x 2.0 m long
210846 Mesh panel, 1.0 m high x 1.0 m long
210847 Mesh panel, 1.0 m high x 2.0 m long
210964 Mesh panel with sliding window
210146 AdaptaPanel swing gate

Note: Each galvanised welded mesh panel comprises 4mm steel wire construction with 50mm grid centres, with rolled wire edge detailing for added strength.

Counterweight Components

Code Component
210576 Counterweight base section, 0.8 m
210577 Counterweight base section, 1.0 m
210578 Counterweight base section, 1.2 m
210579 Galvanised counterweight, 22.5 kg

Impact Testing and Standards

AdaptaPanel is designed and tested to meet the relevant requirements of:

  • AS/NZS 4994.1:2023: Temporary edge protection
  • AS 1657:2018: Fixed platforms, walkways, stairways and ladders, where applicable

The system is tested at the top rail height for its different post heights.

SafeSmart’s testing includes:

  • A 600 N horizontal point load
  • A 350 N/m horizontal distributed load
  • A maximum deflection limit of 100 mm

Testing the load at the top of taller posts is important. Applying a compliant load only at a traditional 1 m rail height does not represent the force placed on a 2 m, 3 m or 4 m barrier.

Compliance depends on the complete configuration, including:

  • Post height
  • Panel arrangement
  • Fixing method
  • Anchor type
  • Concrete or timber substrate
  • Edge distance
  • Attached mesh, curtains or screening
  • Wind loading
  • Gates and openings
  • Installation and inspection

From Site Scoping to Installation

AdaptaPanel is supplied as a configurable system rather than a single standard fence panel, which makes installation easier to plan across different site conditions.

SafeSmart can work with the site, engineering and temporary-works teams to determine:

  • Required barrier heights
  • Top or face mounting
  • Concrete, steel or timber substrates
  • Standard or shallow embedment
  • Counterweight requirements
  • Where to place posts and panels
  • Corners and changes in level
  • Gates and material access
  • Façade work areas
  • Public-interface requirements
  • Wind and attached screening loads
  • Installation stages
  • Storage and relocation
  • Proper installation and maintenance requirements for safety throughout the project lifecycle

The resulting package can include site measurements, layout drawings, engineering calculations, certification, custom components, manufacture, delivery, installer training, inspections and replacement parts.

AdaptaPanel Case Studies

Shellharbour Hospital: WorkThru Edge Protection

BESIX Watpac needed edge protection that could respond to voids, structural ties and changing work areas during the Shellharbour Hospital construction.

AdaptaPanel WorkThru allowed mesh sections to be removed where crews needed access. Sliding toeboards adjusted around ties, columns and void protection. SafeSmart also provided engineering support and on-site installation training.

Read the Shellharbour Hospital WorkThru case study

Castle Hill: Face-Mounted Capping Beam Protection

Dasco had limited room between a capping beam and the site’s perimeter fence. A top-mounted or freestanding barrier would have reduced the space available for storage and pedestrian movement.

SafeSmart supplied a 2 m face-mounted AdaptaPanel system. Fixing the posts to the side of the beam left the upper surface available as a walkway while also providing a taller barrier above the excavation.

Read the Castle Hill capping beam case study

Sydney Metro: Cranked Posts Above a Station Box

Crane operators working above a 30 m deep excavation needed visibility into the station box without leaning over the barrier.

SafeSmart worked with the project team to design a 45-degree cranked post using standard AdaptaPanel panels. The upper section moved away from the operator’s direct viewing line while retaining the required barrier height.

Read the Sydney Metro cranked-post case study

The Bond: Edge Protection on CLT

Buildcorp required edge protection for a cross-laminated timber structure at The Bond project in Bella Vista.

SafeSmart reviewed the lower pull-out strength of the timber substrate and paired standard AdaptaPanel components with selected timber construction screws. This allowed the system to be used during both construction and fit-out.

Read The Bond CLT edge protection case study

Frequently Asked Questions

Is AdaptaPanel temporary or permanent?

AdaptaPanel is primarily designed for temporary and semi-permanent edge protection. Some configurations may be used for longer periods, subject to the approved design, installation, inspection and maintenance requirements.

What heights are available?

Top-mounted posts are available in 1 m, 1.5 m, 2 m, 3 m and 4 m heights. Standard face-mounted posts are available in 1 m, 1.5 m and 2 m heights.

Can AdaptaPanel be installed without drilling?

Yes, in selected configurations. Counterweighted bases and cast-in sleeve systems can be used where surface drilling is restricted. These configurations require project-specific temporary-works design.

Can it be installed on timber?

Yes. The substrate and fixings must be assessed for the timber structure. Standard concrete anchors must not be used as a timber fixing schedule.

Can it follow curved edges?

Yes. Standard panels can be angled at the posts to follow broad curves and circular shafts. Tighter radiuses may require shorter panels or custom infill sections.

Can mesh panels be removed for work at the edge?

The standard system uses retained slide-in panels. Where work must continue through the barrier, AdaptaPanel WorkThru provides removable mesh, sliding toeboards and controlled access components. Integrated kick plates help prevent loose objects from rolling off the edge and reduce the risk of falling objects hitting workers below.

Can screening or acoustic curtains be attached?

Yes, subject to design. Curtains, shade mesh and solid screening increase wind loads and may require different posts, fixings or spacing.

How is the system transported?

Posts and panels can be stacked in dedicated stillages for storage and secured transport.

Does every AdaptaPanel configuration comply automatically?

No. AdaptaPanel components are designed and tested against the relevant standards, but compliance applies to the approved complete configuration. Fixings, substrate, layout, height, loads and installation must all be checked.

More AdaptaPanel Information

Need Edge Protection for a Changing Workface?

Send SafeSmart your drawings, perimeter lengths, required heights, substrate details, construction sequence and access requirements so we can plan project-specific layouts and fixings designed specifically for the build sequence.

Our team can scope, design, engineer and deliver an AdaptaPanel edge protection system around the way the project will actually be built, helping keep changing workfaces protected and reduce risks from falls.

Suggested for you

Your solution is just a click away

The Solution Selector will recommend the best access solution for your needs in 30 seconds.

The SafeSmart Difference